Hazards and Warnings
Manufacturer is not responsible for user’s failure to comply with the instructions contained in this manual.Any service performed on this product must be completed by a qualified individual.Replacement of this product must be performed by a qualified individual.Failure to use
Presentation
As the Tyness enables a wireless connection in LoRa mode to a data concentrator, the TYNESS-OPT-MBUS board was designed to read counters located near the Tyness. The M-Bus protocol is a standardized protocol according to the European standard EN 13757. A
References
TYNESS-OPT-MBUS Additional M-BUS Board enabling to read field M-Bus sensors (M-Bus slaves) counters of calories, water, and electrical energy. Comprises a power supply 230 V AC – 36 V DC for the TYNESS ENERGY and TYNESS MODULAR Ewattch which is necessary for
Usage
The board can be set up on: the TYNESS ENERGY (1 location) the TYNESS MODULAR (2 locations). The board comprises two terminal blocks of type WAGO series 20599. One terminal block for the M-Bus connection cable (a standard telephone cable – jYStY
Technical specifications
Dimensions: 1 additional standard location for Tyness Connectors : 1 connector type WAGO series 2059 for the bus M-Bus (0.14 to 0.34 mm2- 26 to 22 AWG) 1 connector type WAGO series 2059 for the power supply (0.14 to 0.34 mm2- 26
Implementation
Above all, the Tyness and the board must be disconnected. The board must be installed carefully and with precision of the connectors on the locations EXT.1 and/or EXT.2 of the Tyness. The M-Bus bus cable of the type standard telephone cable – jYStY
Settings
The board is configured with the Tyness Configurator software. Always use the latest version of the Tyness Configurator and check that your Tyness has the latest version of the firmware. If necessary, carry out an update. Step 1 ● Click on “Config” of the
Description and usage
The board can be set up on: ● the sensors TYNESS ENERGY (1 location) ● the TYNESS MODULAR sensors (2 locations) The board functions in communication mode ModBus RTU RS485. The transmission speed is configurable from 1200 to 57600 bauds. It is comprised of one
Technical specifications
Dimensions: 1 additional standard location for Tyness Connectors: 1 connector, 3 terminals, type AVX series 9276 (2/10° to 8/10° - 18 to 24 AWG) rigid and flexible multi-strands Number of M-BUS slaves: 15 slave maximum Radio data: 40 bytes per radio transmission
Implementation and wiring
Pinout of the terminal block: Configuration with the: The resistances of polarization Pull Up and Pull Down must only be installed in a single place of the Bus, usually at the level of the master. In this case, move switches 2 and 3