Technical specifications
Dimensions: 1 additional standard location for Tyness Connectors: ● 1 connector ● 8 terminals type AVX series 9276 (2/10° to 8/10° - 24 to 18 AWG) ● Rigid and flexible multi-strands Number of inputs: 4 individually configurable inputs in 0-10V or 4-20mA with common mass in all of
Settings
The board is configured with the Tyness Configurator software. Always use the latest version of the Tyness Configurator and check that your Tyness has the latest version of the firmware. If necessary, carry out an update. Configuration steps 1 – Click on “Config” of
Sensor supply
Certain sensors are powered by the data loop. In this case, a power supply must be integrated into the loop according to the following diagram where the receptor corresponds to the TYNESS- OPT-ANA board and the Transmitter corresponds to the sensor read. The 0V
Payload descriptions
A Tyness fitted with an ANA board transmits its data in a raw format on the different LoRaWAN networks. The section below shows you how to decode the frames (Payload) sent by the Tyness.
Payload descriptions
A Tyness fitted with an M-BUS board transmits its data in raw format on the different LoRaWAN networks. The section below shows you how to decode the frames (Payload) sent by the Tyness. The following table describes the encoding of the data in
Implementation
Above all, the Tyness and the board must be disconnected. The board must be installed carefully and with precision of the connectors on the locations EXT.1 and/or EXT.2 of the Tyness. The M-Bus bus cable of the type standard telephone cable – jYStY
Settings
The board is configured with the Tyness Configurator software. Always use the latest version of the Tyness Configurator and check that your Tyness has the latest version of the firmware. If necessary, carry out an update. Step 1 ● Click on “Config” of the
Presentation
As the Tyness enables a wireless connection in LoRa mode to a data concentrator, the TYNESS-OPT-MBUS board was designed to read counters located near the Tyness. The M-Bus protocol is a standardized protocol according to the European standard EN 13757. A
Usage
The board can be set up on: the TYNESS ENERGY (1 location) the TYNESS MODULAR (2 locations). The board comprises two terminal blocks of type WAGO series 20599. One terminal block for the M-Bus connection cable (a standard telephone cable – jYStY
Technical specifications
Dimensions: 1 additional standard location for Tyness Connectors : 1 connector type WAGO series 2059 for the bus M-Bus (0.14 to 0.34 mm2- 26 to 22 AWG) 1 connector type WAGO series 2059 for the power supply (0.14 to 0.34 mm2- 26