{"id":6977,"date":"2026-03-05T15:27:27","date_gmt":"2026-03-05T14:27:27","guid":{"rendered":"https:\/\/ewattch-documentation.com\/?p=6977"},"modified":"2026-03-05T15:31:36","modified_gmt":"2026-03-05T14:31:36","slug":"configuration-dun-capteur-3","status":"publish","type":"post","link":"https:\/\/ewattch-documentation.com\/?p=6977","title":{"rendered":"Configuration d&#8217;un capteur"},"content":{"rendered":"<p>The following steps describe how to configure the Multitech as a LoRa to Modbus TCP gateway.<\/p>\n<p>Start by connecting to the web interface of your Multitech.<\/p>\n<h6>Provisioning<\/h6>\n<p>Go to the <strong>&#8220;Provisioning&#8221;<\/strong> section.<\/p>\n<ul>\n<li>Enter a name for your sensor<\/li>\n<li>Select its type<\/li>\n<li>Enter its three LoRaWAN keys (DevEUI, AppEUI, and AppKey)<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4018 size-large\" src=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/01-provisionning-1024x492.png\" alt=\"\" width=\"1024\" height=\"492\" srcset=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/01-provisionning-1024x492.png 1024w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/01-provisionning-300x144.png 300w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/01-provisionning-150x72.png 150w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/01-provisionning-768x369.png 768w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/01-provisionning.png 1402w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<h6>Enabling Modbus<\/h6>\n<p>Your sensor now appears in the <strong>&#8220;My sensors&#8221;<\/strong> section.<\/p>\n<ul>\n<li>Click the arrow on the left of the sensor to expand it<\/li>\n<li>Click the gear icon to access its settings<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4017 size-large\" src=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/02-sensors-1024x389.png\" alt=\"\" width=\"1024\" height=\"389\" srcset=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/02-sensors-1024x389.png 1024w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/02-sensors-300x114.png 300w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/02-sensors-150x57.png 150w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/02-sensors-768x292.png 768w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/02-sensors.png 1383w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<ul>\n<li>Check the <strong>&#8220;Modbus TCP&#8221;<\/strong> box<\/li>\n<li>Click the <strong>&#8220;CONFIRM&#8221;<\/strong> button to enable Modbus for this sensor<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4016 size-large\" src=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/03-enable-modbus-tcp-1024x491.png\" alt=\"\" width=\"1024\" height=\"491\" srcset=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/03-enable-modbus-tcp-1024x491.png 1024w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/03-enable-modbus-tcp-300x144.png 300w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/03-enable-modbus-tcp-150x72.png 150w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/03-enable-modbus-tcp-768x368.png 768w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/03-enable-modbus-tcp.png 1399w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<h6>Data Configuration<\/h6>\n<p>The next steps describe how to add the sensor data to the Multitech Modbus table.<\/p>\n<ul>\n<li>First, the Multitech must receive a transmission containing the sensor data. The received data will appear in the sensors section.<\/li>\n<li>Then click the gear icon to access the sensor configuration<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4015 size-large\" src=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/04-sensor-first-com-1024x473.png\" alt=\"\" width=\"1024\" height=\"473\" srcset=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/04-sensor-first-com-1024x473.png 1024w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/04-sensor-first-com-300x139.png 300w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/04-sensor-first-com-150x69.png 150w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/04-sensor-first-com-768x355.png 768w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/04-sensor-first-com.png 1379w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<ul>\n<li>Click the gear icon again to access the sensor Modbus configuration<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4014 size-large\" src=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/05-start-configure-modbus-tcp-1024x499.png\" alt=\"\" width=\"1024\" height=\"499\" srcset=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/05-start-configure-modbus-tcp-1024x499.png 1024w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/05-start-configure-modbus-tcp-300x146.png 300w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/05-start-configure-modbus-tcp-150x73.png 150w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/05-start-configure-modbus-tcp-768x374.png 768w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/05-start-configure-modbus-tcp.png 1412w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p>The received data is listed on this page.<\/p>\n<ul>\n<li>Select in the <strong>&#8220;Enable&#8221;<\/strong> column the data to add to the Modbus table<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4013 size-large\" src=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/06-before-activate-sensors-1024x628.png\" alt=\"\" width=\"1024\" height=\"628\" srcset=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/06-before-activate-sensors-1024x628.png 1024w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/06-before-activate-sensors-300x184.png 300w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/06-before-activate-sensors-150x92.png 150w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/06-before-activate-sensors-768x471.png 768w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/06-before-activate-sensors.png 1392w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p>For each data point, it is possible to configure its format in the Modbus table, a scaling multiplication factor, its address in the table, and its endianness.<br \/>\nThe <strong>&#8220;AUTO FILL&#8221;<\/strong> button automatically assigns Modbus addresses to the data.<\/p>\n<ul>\n<li>Configure your data<\/li>\n<li>Click the <strong>&#8220;CONFIRM&#8221;<\/strong> button<\/li>\n<\/ul>\n<p>The next data received by the Multitech will now be written and available in the Modbus table.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4012 size-large\" src=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/07-after-activate-sensors-1024x638.png\" alt=\"\" width=\"1024\" height=\"638\" srcset=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/07-after-activate-sensors-1024x638.png 1024w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/07-after-activate-sensors-300x187.png 300w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/07-after-activate-sensors-150x93.png 150w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/07-after-activate-sensors-768x479.png 768w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/07-after-activate-sensors.png 1351w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The following steps describe how to configure the Multitech as a LoRa to Modbus TCP gateway. Start by connecting to the web interface of your Multitech. Provisioning Go to the &#8220;Provisioning&#8221; section. Enter a name for your sensor Select its [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[47],"tags":[],"class_list":["post-6977","post","type-post","status-publish","format-standard","hentry","category-non-classe-fr"],"_links":{"self":[{"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/posts\/6977","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6977"}],"version-history":[{"count":1,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/posts\/6977\/revisions"}],"predecessor-version":[{"id":6984,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/posts\/6977\/revisions\/6984"}],"wp:attachment":[{"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6977"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=6977"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=6977"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}