{"id":6653,"date":"2026-02-20T16:24:59","date_gmt":"2026-02-20T15:24:59","guid":{"rendered":"https:\/\/ewattch-documentation.com\/?p=6653"},"modified":"2026-02-20T16:31:00","modified_gmt":"2026-02-20T15:31:00","slug":"installation-et-mise-en-oeuvre-17","status":"publish","type":"post","link":"https:\/\/ewattch-documentation.com\/?p=6653","title":{"rendered":"Installation et mise en \u0153uvre"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-3808 size-medium\" src=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/Danger_Risk_Of_Electric_Shock._Disconnect_All_Sources_Of_Supply_Prior_To_Servicing_3x1_75_4_25x1_75_5_5x2_5_grande-300x139.png\" alt=\"\" width=\"300\" height=\"139\" srcset=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/Danger_Risk_Of_Electric_Shock._Disconnect_All_Sources_Of_Supply_Prior_To_Servicing_3x1_75_4_25x1_75_5_5x2_5_grande-300x139.png 300w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/Danger_Risk_Of_Electric_Shock._Disconnect_All_Sources_Of_Supply_Prior_To_Servicing_3x1_75_4_25x1_75_5_5x2_5_grande-150x70.png 150w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/Danger_Risk_Of_Electric_Shock._Disconnect_All_Sources_Of_Supply_Prior_To_Servicing_3x1_75_4_25x1_75_5_5x2_5_grande.png 600w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<h5 style=\"text-align: center;\">Prerequisites<\/h5>\n<ul>\n<li>1x TYNESS-MODBUS or TYNESS-MODBUS-4G: intelligent sensor communicating via LoRa or 4G<\/li>\n<li>Available space allowing the TYNESS-MODBUS to be mounted<\/li>\n<li>50\/60Hz 100 to 240 VAC power supply for wiring the 5VDC power supply<\/li>\n<\/ul>\n<h5 style=\"text-align: center;\">Wiring<\/h5>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-large wp-image-6288\" src=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/ca\u0302blage-modbus-1024x683.png\" alt=\"\" width=\"1024\" height=\"683\" srcset=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/ca\u0302blage-modbus-1024x683.png 1024w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/ca\u0302blage-modbus-300x200.png 300w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/ca\u0302blage-modbus-150x100.png 150w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/ca\u0302blage-modbus-768x512.png 768w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/ca\u0302blage-modbus-450x300.png 450w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/ca\u0302blage-modbus.png 1536w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<h5 style=\"text-align: center;\">Installation<\/h5>\n<p style=\"text-align: left;\"><span style=\"color: #2aba56;\"><strong>DIN Rail Mounting<\/strong><\/span><\/p>\n<p>The TYNESS-FIX-RAIL consists of 2 parts: a base and a movable, adjustable tab.<br \/>\nIt is used to mount the Tyness horizontally or vertically on a DIN rail. Asymmetrical, it allows the Tyness to be positioned at two different heights for each orientation.<\/p>\n<p>The Tyness can be removed from the DIN rail by operating the movable tab with a screwdriver, as with any similar mounting system.<br \/>\nIt is supplied with 2 mounting screws.<\/p>\n<p style=\"text-align: left;\"><span style=\"color: #2aba56;\"><strong>Installation steps:<\/strong><\/span><\/p>\n<ol>\n<li>Pre-position the bracket in the chosen orientation (horizontal or vertical) and at the desired height.<\/li>\n<li>If necessary, adjust the height of the tab (see diagram page 13).<\/li>\n<li>Tighten the two screws.<\/li>\n<\/ol>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-8499 size-full\" src=\"\/wp-content\/uploads\/TYNESS_LoRaWAN\/Capture-d\u2019\u00e9cran-2019-07-22-\u00e0-15.08.29.png\" alt=\"\" width=\"1002\" height=\"816\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-8500\" src=\"\/wp-content\/uploads\/TYNESS_LoRaWAN\/Capture-d\u2019\u00e9cran-2019-07-22-\u00e0-15.08.50.png\" alt=\"\" width=\"894\" height=\"278\" \/><\/p>\n<p style=\"text-align: left;\"><span style=\"color: #2aba56;\"><strong>Tab adjustment:<\/strong><\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-8501 size-full\" src=\"\/wp-content\/uploads\/TYNESS_LoRaWAN\/Capture-d\u2019\u00e9cran-2019-07-22-\u00e0-15.11.03.png\" alt=\"\" width=\"953\" height=\"560\" \/><\/p>\n<p>Depending on the position of the FIX-RAIL, the height of the tab must be adjusted so that it remains accessible.<\/p>\n<p>When the upper part of the tab protrudes from the Tyness (for example, with a Tyness in a low axial position), it can be trimmed using cutting pliers.<\/p>\n<h5 style=\"text-align: center;\">Configuration on Ewattch Cloud<\/h5>\n<p>Once installed, the Tyness can be integrated into the Ewattch Cloud platform via a compatible LoRaWAN gateway. This integration enables:<\/p>\n<ul>\n<li>Real-time monitoring of transmitted measurements.<\/li>\n<li>Generation of customized reports.<\/li>\n<li>Receipt of alerts in the event of malfunction or predefined threshold exceedance.<\/li>\n<\/ul>\n<p>To simplify adding your sensors to Ewattch Cloud, you can use the Scan to Cloud feature, an intuitive solution that streamlines provisioning in just a few clicks.<\/p>\n<h5 style=\"text-align: center;\">Access the full Scan to Cloud documentation:<\/h5>\n<p><a href=\"https:\/\/ewattch-documentation.com\/?scan_to_cloud\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5822\" src=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/Scan-to-Cloud-1024x591.png\" alt=\"\" width=\"600\" height=\"346\" srcset=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/Scan-to-Cloud-1024x591.png 1024w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/Scan-to-Cloud-300x173.png 300w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/Scan-to-Cloud-150x86.png 150w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/Scan-to-Cloud-768x443.png 768w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/Scan-to-Cloud-1536x886.png 1536w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Prerequisites 1x TYNESS-MODBUS or TYNESS-MODBUS-4G: intelligent sensor communicating via LoRa or 4G Available space allowing the TYNESS-MODBUS to be mounted 50\/60Hz 100 to 240 VAC power supply for wiring the 5VDC power supply Wiring Installation DIN Rail Mounting The TYNESS-FIX-RAIL [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[47],"tags":[],"class_list":["post-6653","post","type-post","status-publish","format-standard","hentry","category-non-classe-fr"],"_links":{"self":[{"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/posts\/6653","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6653"}],"version-history":[{"count":1,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/posts\/6653\/revisions"}],"predecessor-version":[{"id":6664,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/posts\/6653\/revisions\/6664"}],"wp:attachment":[{"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6653"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=6653"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=6653"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}