{"id":3601,"date":"2024-03-21T15:41:17","date_gmt":"2024-03-21T14:41:17","guid":{"rendered":"https:\/\/beta.ewattch-documentation.com\/?p=3601"},"modified":"2024-03-21T15:41:17","modified_gmt":"2024-03-21T14:41:17","slug":"additional-boards-3","status":"publish","type":"post","link":"https:\/\/ewattch-documentation.com\/?p=3601","title":{"rendered":"Additional boards"},"content":{"rendered":"<p>Every Tyness extension board has its own data sheet. To consult the documentation, click on the image which will send you back to the documentation of this one.<\/p>\n<h5><span style=\"color: #000000;\"><strong>References<\/strong><\/span><\/h5>\n<p><a href=\"\/?page_id=1193\"><strong><span style=\"color: #2aba56;\">\u2022 TYNESS-OPT-ANA<\/span><\/strong><\/a><\/p>\n<p><a href=\"\/?page_id=1193\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-8535\" src=\"\/wp-content\/uploads\/TYNESS_LoRaWAN_-_English\/Capture-d\u2019\u00e9cran-2019-07-23-\u00e0-09.14.57.png\" alt=\"\" width=\"613\" height=\"322\" \/><\/a><\/p>\n<p>The TYNESS-OPT-ANA board is an extension board with 4 analogue inputs configurable in 0-10V and 4-20 mA with common ground. It reads information from any sensor with 0-10V and \/ or 4-20 mA analog output<br \/>\nExample : a PLC, a variable speed drive, a flow meter, etc.<\/p>\n<p><a href=\"\/?page_id=1191\"><strong><span style=\"color: #2aba56;\">\u2022\u00a0TYNESS-OPT-MBUS<\/span><\/strong><\/a><\/p>\n<p><a href=\"\/?page_id=1191\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-8536\" src=\"\/wp-content\/uploads\/TYNESS_LoRaWAN_-_English\/Capture-d\u2019\u00e9cran-2019-07-23-\u00e0-09.15.05.png\" alt=\"\" width=\"554\" height=\"320\" \/><\/a><\/p>\n<p>M-BUS extension board to pick up M-Bus field sensors (M-Bus slaves) such as calorie, water, electrical energy meters&#8230;<\/p>\n<p><a href=\"\/?page_id=1195\"><strong><span style=\"color: #2aba56;\">\u2022 TYNESS-OPT-PT100<\/span><\/strong><\/a><\/p>\n<p><a href=\"\/?page_id=1195\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-8537 size-full\" src=\"\/wp-content\/uploads\/TYNESS_LoRaWAN_-_English\/Capture-d\u2019\u00e9cran-2019-07-23-\u00e0-09.15.17.png\" alt=\"\" width=\"869\" height=\"379\" \/><\/a><\/p>\n<p>The TYNESS-OPT-PT100 board is extension board with 4 inputs for temperature measurement by PT100 3-wire probes.<\/p>\n<p><a href=\"\/?page_id=1205\"><span style=\"color: #2aba56;\"><strong>\u2022 TYNESS-OPT-ROGOW<\/strong><\/span><\/a><\/p>\n<p><a href=\"\/?page_id=1205\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-8538\" src=\"\/wp-content\/uploads\/TYNESS_LoRaWAN_-_English\/Capture-d\u2019\u00e9cran-2019-07-23-\u00e0-09.21.57.png\" alt=\"\" width=\"284\" height=\"333\" \/><\/a><\/p>\n<p>This extension board has 3 current measurement inputs by soft loops (Rogowski)<\/p>\n<p><a href=\"\/?page_id=1188\"><span style=\"color: #2aba56;\"><strong>\u2022 TYNESS-OPT-MODBUS<\/strong><\/span><\/a><\/p>\n<p><a href=\"\/?page_id=1188\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-8539\" src=\"\/wp-content\/uploads\/TYNESS_LoRaWAN_-_English\/Capture-d\u2019\u00e9cran-2019-07-23-\u00e0-09.23.24.png\" alt=\"\" width=\"223\" height=\"323\" \/><\/a><\/p>\n<p>The MODBUS extension board has a ModBus interface for communicating in master or slave mode.<\/p>\n<p><a href=\"\/?page_id=1205\"><span style=\"color: #2aba56;\"><strong>\u2022 TYNESS-OPT-CURR<\/strong><\/span><\/a><\/p>\n<p><a href=\"\/?page_id=1205\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-8540\" src=\"\/wp-content\/uploads\/TYNESS_LoRaWAN_-_English\/Capture-d\u2019\u00e9cran-2019-07-23-\u00e0-09.25.04.png\" alt=\"\" width=\"202\" height=\"302\" \/><\/a><\/p>\n<p>This board has 3 current measurement inputs with clip-in clips (not included)<\/p>\n<p><a href=\"\/?page_id=1185\"><span style=\"color: #2aba56;\"><strong>\u2022 TYNESS-OPT-DIGITAL-2IN<\/strong><\/span><\/a><\/p>\n<p><a href=\"\/?page_id=1185\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-9621 size-full\" src=\"\/wp-content\/uploads\/TYNESS_LoRaWAN_-_English\/2DI.png\" alt=\"\" width=\"245\" height=\"294\" \/><\/a><\/p>\n<p>This extension board has 2 digital inputs allowing the data of all types of meters to be traced with a dry contact type pulse output.<\/p>\n<p><span style=\"color: #2aba56;\"><strong><br \/>\n<\/strong><\/span><a href=\"\/?page_id=1185\"><span style=\"color: #2aba56;\"><strong>\u00a0 \u00a0 \u2022 TYNESS-OPT-2IN-12_24V_DC \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0<span style=\"color: #2aba56;\"> \u2022 TYNESS-OPT-2IN-12_24V_AC<\/span><\/strong><\/span><\/a><\/p>\n<p><a href=\"\/?page_id=1185\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-8541 size-full\" src=\"\/wp-content\/uploads\/TYNESS_LoRaWAN_-_English\/Capture-d\u2019\u00e9cran-2019-07-23-\u00e0-09.30.57.png\" alt=\"\" width=\"723\" height=\"338\" \/><\/a><\/p>\n<p>These extension boards make it possible to detect the 12-24V AC or DC voltage: pulse counting, state detection, time counting, etc.<\/p>\n<p><a href=\"\/?page_id=1197\"><span style=\"color: #2aba56;\"><strong>\u2022 TYNESS-OPT-OPTIC<\/strong><\/span><\/a><\/p>\n<p><a href=\"\/?page_id=1197\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-8410 aligncenter\" src=\"\/wp-content\/uploads\/TYNESS_LoRaWAN_-_English\/TYNESS-OPT-OPTIC.png\" alt=\"\" width=\"337\" height=\"334\" \/><\/a><\/p>\n<p>This extension board has 2 optical sensor inputs capable of counting light pulses.<br \/>\nUse case: interfacing with an electricity meter using its blinking LED.<\/p>\n<p><a href=\"\/?page_id=2184\"><span style=\"color: #2aba56;\"><strong>\u2022 TYNESS-OPT-MULTI-IN<\/strong><\/span><\/a><\/p>\n<p><a href=\"\/?page_id=2184\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10459 size-full\" src=\"\/wp-content\/uploads\/TYNESS_LoRaWAN_-_English\/Tyness-multi-in.jpg\" alt=\"\" width=\"300\" height=\"300\" \/><\/a>This additional card has 2 24V analog inputs, 2 12 to 24V digital inputs, and 2 temperature inputs via PT100.<br \/>\nExample of use: Interfacing with a production machine.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Every Tyness extension board has its own data sheet. To consult the documentation, click on the image which will send you back to the documentation of this one. References \u2022 TYNESS-OPT-ANA The TYNESS-OPT-ANA board is an extension board with 4 [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[47],"tags":[],"class_list":["post-3601","post","type-post","status-publish","format-standard","hentry","category-non-classe-fr"],"_links":{"self":[{"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/posts\/3601","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3601"}],"version-history":[{"count":0,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/posts\/3601\/revisions"}],"wp:attachment":[{"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3601"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=3601"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=3601"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}