{"id":3140,"date":"2024-03-07T09:11:44","date_gmt":"2024-03-07T08:11:44","guid":{"rendered":"https:\/\/beta.ewattch-documentation.com\/?p=3140"},"modified":"2024-04-05T08:59:34","modified_gmt":"2024-04-05T06:59:34","slug":"installation-du-produit-25","status":"publish","type":"post","link":"https:\/\/ewattch-documentation.com\/?p=3140","title":{"rendered":"Installation du produit"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1845 size-full\" src=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/SQUID_V2_-_English\/Capture-d\u2019\u00e9cran-2019-08-20-\u00e0-15.59.10.png\" alt=\"\" width=\"843\" height=\"708\" srcset=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/SQUID_V2_-_English\/Capture-d\u2019\u00e9cran-2019-08-20-\u00e0-15.59.10.png 843w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/SQUID_V2_-_English\/Capture-d\u2019\u00e9cran-2019-08-20-\u00e0-15.59.10-300x252.png 300w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/SQUID_V2_-_English\/Capture-d\u2019\u00e9cran-2019-08-20-\u00e0-15.59.10-150x126.png 150w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/SQUID_V2_-_English\/Capture-d\u2019\u00e9cran-2019-08-20-\u00e0-15.59.10-768x645.png 768w\" sizes=\"auto, (max-width: 843px) 100vw, 843px\" \/><\/p>\n<h6><span style=\"color: #000000;\"><strong>Mounting and Disassembly<\/strong><\/span><\/h6>\n<div class=\"page\" title=\"Page 6\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>This equipment must be installed on a horizontal DIN rail of 35mm in the electrical panel. Be sure to lock the product securely onto the DIN rail.<span class=\"Apple-converted-space\">\u00a0<\/span><\/p>\n<p>Allow a space of 5 modules to install the product in the electrical panel. To disassemble, use a flat screwdriver to unlock the black clip at the bottom of the device.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<h6><span style=\"color: #000000;\"><strong>Prerequisites<\/strong><\/span><\/h6>\n<div class=\"page\" title=\"Page 6\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>A 5V DC-2A power supply must be used to power the SQUID. The wiring of the Safety Extra Low Voltage circuits must be maintained and kept separated from circuits carrying hazardous voltages.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<ul>\n<li>Connecting the current sensors \u00a0<img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1853 alignnone\" src=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/SQUID_V2\/Capture-d\u2019\u00e9cran-2019-07-10-\u00e0-16.27.06.png\" alt=\"\" width=\"39\" height=\"40\" \/><\/li>\n<\/ul>\n<div class=\"page\" title=\"Page 7\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Connect the measurement probes to the 12 connectors on the top and bottom of the device.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1848 size-full\" src=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/SQUID_V2_-_English\/Capture-d\u2019\u00e9cran-2019-08-20-\u00e0-16.06.04.png\" alt=\"\" width=\"758\" height=\"861\" srcset=\"https:\/\/ewattch-documentation.com\/wp-content\/uploads\/SQUID_V2_-_English\/Capture-d\u2019\u00e9cran-2019-08-20-\u00e0-16.06.04.png 758w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/SQUID_V2_-_English\/Capture-d\u2019\u00e9cran-2019-08-20-\u00e0-16.06.04-264x300.png 264w, https:\/\/ewattch-documentation.com\/wp-content\/uploads\/SQUID_V2_-_English\/Capture-d\u2019\u00e9cran-2019-08-20-\u00e0-16.06.04-132x150.png 132w\" sizes=\"auto, (max-width: 758px) 100vw, 758px\" \/><\/p>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Mounting and Disassembly This equipment must be installed on a horizontal DIN rail of 35mm in the electrical panel. Be sure to lock the product securely onto the DIN rail.\u00a0 Allow a space of 5 modules to install the product [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[47],"tags":[],"class_list":["post-3140","post","type-post","status-publish","format-standard","hentry","category-non-classe-fr"],"_links":{"self":[{"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/posts\/3140","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3140"}],"version-history":[{"count":1,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/posts\/3140\/revisions"}],"predecessor-version":[{"id":3947,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=\/wp\/v2\/posts\/3140\/revisions\/3947"}],"wp:attachment":[{"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3140"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=3140"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ewattch-documentation.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=3140"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}